کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1212411 1494081 2014 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development and validation of an ultra high performance liquid chromatography tandem mass spectrometry method for simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk
ترجمه فارسی عنوان
توسعه و اعتبار سنجی از روش کروماتوگرافی مایع فوق العاده با عملکرد بالا برای تعیین همزمان سولفونامید ها، کینولون ها و بنزیمیدازول ها در شیر گاو
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A LC–MS/MS method was developed for 46 veterinary drugs in bovine milk.
• A simple pretreatment procedure based on OASIS® MCX SPE had been established.
• Selectivity, linearity, trueness, precision, CCα, and CCβ had been validated.
• The whole method was reliable, convenient and sensitive.

A simple, sensitive and reliable analytical method was developed for the simultaneous determination of 38 veterinary drugs (18 sulfonamides, 11 quinolones and 9 benzimidazoles) and 8 metabolites of benzimidazoles in bovine milk by ultra high performance liquid chromatography-positive electrospray ionization tandem mass spectrometry (UHPLC–ESI-MS/MS). Samples were extracted with acidified acetonitrile, cleaned up with Oasis® MCX cartridges, and analyzed by LC–MS/MS on an Acquity UPLC® BEH C18 column with gradient elution. The method allows such multi-analyte measurements within a 13 min runtime while the specificity is ensured through the MRM acquisition mode. The method was validated according to the European Commission Decision 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), recovery, precision, linearity and stability. For compounds which have MRLs in bovine milk, the CCα values fall into a range from 11 to 115 μg/kg, and the CCβ values fall within a range of 12–125 μg/kg. For compounds which have not MRLs in bovine milk, the CCα values fall into a range from 0.01 to 0.08 μg/kg, and the CCβ values fall within a range of 0.02–0.11 μg/kg. The mean recoveries of the 46 analytes were between 87 and 119%. The calculated RSD values of repeatability and within-laboratory reproducibility experiments were below 11% and 15% for the 46 compounds, respectively. The method was demonstrated to be suitable for the simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 962, 1 July 2014, Pages 20–29
نویسندگان
, , , , , , ,