کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1212546 1494074 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of phenolic acids and flavonoids in raw propolis by silica-supported ionic liquid-based matrix solid phase dispersion extraction high performance liquid chromatography-diode array detection
ترجمه فارسی عنوان
تعیین اسید فنولیک و فلاونوئیدها در پروپولیس خام با استفاده از سیلیکا پشتیبانی مایع بر پایه مایع اکسید جامد پراکندگی با کارایی بالا عملکرد کروماتوگرافی مایع تشخیص آرایه دیود
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• The silica-supported ionic liquid (S-SIL) was prepared.
• S-SIL-based matrix solid-phase dispersant (MSPD) was developed.
• Eight phenolic acids and flavonoids in raw propolis were extracted and determined.
• The present method combined the advantages of MSPD and IL.
• Compared with other methods, shorter time and fewer samples were used.

The silica-supported ionic liquid (S-SIL) was prepared by impregnation and used as the dispersion adsorbent of matrix solid phase dispersion (MSPD) for the simultaneous extraction of eight phenolic acids and flavonoids, including caffeic acid, ferulic acid, morin, luteolin, quercetin, apigenin, chrysin, and kaempferide in raw propolis. High performance liquid chromatography with a Zorbax SB-C18 column (150 mm × 4.6 mm, 3.5 μm) was used for separation of the analytes. The mobile phase consisted of 0.2% phosphoric acid aqueous solution and acetonitrile and the flow rate of the mobile phase was 0.5 mL/min. The experimental conditions for silica-supported ionic liquid-based matrix solid phase dispersion (S-SIL-based MSPD) were optimized. S-SIL containing 10% [C6MIM]Cl was used as dispersant, 20 mL of n-hexane as washing solvent and 15 mL of methanol as elution solvent. The ratio of S-SIL to sample was selected to be 4:1. The standard curves showed good linear relationship (r > 0.9995). The limits of detection and quantification were in the range of 5.8–22.2 ng mL−1 and 19.2–74.0 ng mL−1, respectively. The relative standard deviations (RSDs) of intra-day and inter-day determination were lower than 8.80% and 11.19%, respectively. The recoveries were between 65.51% and 92.32% with RSDs lower than 8.95%. Compared with ultrasound-assisted extraction (UAE) and soxhlet extraction, the present method consumed less sample, organic solvent, and extraction time, although the extraction yields obtained by S-SIL-based MSPD are slightly lower than those obtained by UAE.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 969, 15 October 2014, Pages 205–212
نویسندگان
, , , , , , , , ,