کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1213397 1494128 2012 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Chemometric resolution of coeluting peaks of eleven antihypertensives from multiple classes in high performance liquid chromatography: A comprehensive research in human serum, health product and Chinese patent medicine samples
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Chemometric resolution of coeluting peaks of eleven antihypertensives from multiple classes in high performance liquid chromatography: A comprehensive research in human serum, health product and Chinese patent medicine samples
چکیده انگلیسی

A novel chemometric-assisted high performance liquid chromatography method coupled with diode array detector (HPLC-DAD) was presented for the simultaneous determination of eleven antihypertensives from multiple classes in most concerned matrix systems. With the aid of second-order calibration which enables specific information of analytes to be well extracted, the heavily overlapping profiles between analytes and the coeluting interferences can be successfully separated and thus accurately quantified. A great advantage of the novel strategy lies in the fact that the analysis could be carried out with the same isocratic mobile phase (methanol/KH2PO4: 58:42, v/v, pH 2.60) in a short time regardless of the changes of matrices, such as human serum, health product and Chinese patent medicine. Both qualitative and quantitative results indicate that the hybrid strategy that using HPLC-DAD coupled with second-order chemometric method would be a high performance approach for the purpose of simultaneously quantifying multiple classes of antihypertensives in complex systems. Additionally, the analytical strategy can potentially benefit drug monitoring in both therapeutic research and pharmaceutical quality control. Moreover, the accuracy and reliability of the proposed methodology has been evaluated using several statistical parameters such as root mean squared error of prediction (RMSEP), figures of merit (FOM) and reproducibility of inter-day analysis.


► Eleven antihypertensives were simultaneously assayed in isocratic mode within 10 min.
► The proposed method enables a comprehensive study in three most concerned systems.
► The method provides a more general condition for analyses in various systems.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 902, 1 August 2012, Pages 96–107
نویسندگان
, , , , , , , , ,