کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1216007 | 1494189 | 2006 | 6 صفحه PDF | دانلود رایگان |
We have developed a specific assay for cisplatin in human plasma ultrafiltrate (PUF) and cell culture medium ultrafiltrate (MUF) using HPLC on-line with inductively coupled plasma mass spectrometry (ICP-MS). Separation of cisplatin (6 min) and monohydrated cisplatin (12 min) was achieved using a μBondapak C18 column (Waters) and a mobile phase (0.075 mM sodium dodecyl sulfate and 3% methanol, adjusted to pH 2.5 with triflic acid) pumped at a flow rate of 0.5 mL/min. The analytes were detected with little background interference by ICP-MS monitoring of platinum masses (m/z 194/195). Calibration curves were linear over three orders of magnitude (0.05–8 μM) and the limit of quantitation was 0.1 μM. Intra- and inter-assay accuracy (range 91.6–113%) and precision (range 1.00–12.3%) were acceptable for PUF and MUF. The method was applied to determining cisplatin during ex vivo incubation of the drug in whole human blood at 37 °C. In conclusion, a specific, sensitive and reliable HPLC–ICP-MS assay has been established for determining intact cisplatin in PUF and MUF.
Journal: Journal of Chromatography B - Volume 837, Issues 1–2, 6 June 2006, Pages 29–34