کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1216818 1494194 2006 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of free ertapenem in plasma and bronchoalveolar lavage by high-performance liquid chromatography with ultraviolet detection
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Determination of free ertapenem in plasma and bronchoalveolar lavage by high-performance liquid chromatography with ultraviolet detection
چکیده انگلیسی

A sensitive assay for the determination of unbound ertapenem in human plasma and bronchoalveolar lavage (BAL) was developed using ultrafiltration of plasma and BAL samples. A rapid HPLC method was used with ultraviolet detection set at a wavelength of 305 nm and a separation on a Prontosil AQ C18 column, with imipenem used as internal standard. This assay was linear over the concentration range of 0.5–100 μg/mL and 0.25–50 μg/mL in plasma and BAL, respectively. Limits of detection and quantitation were respectively 0.05 and 0.25 μg/mL. Validation data for accuracy and precision were CV < 2.48 and 8.25%, accuracy in the range 98.1–104.2% and 102.2–108.4%, respectively, for intra and inter-day.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 830, Issue 2, 18 January 2006, Pages 218–223
نویسندگان
, , , , , , , ,