کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1230476 | 1495247 | 2014 | 4 صفحه PDF | دانلود رایگان |

• A new chemiluminescence system with diperiodatonickelate.
• The possible CL emission mechanism briefly discussed.
• Successfully applied to the determination of adrenaline in pharmaceutical preparations.
A novel chemiluminescence (CL) system with diperiodatonickelate (IV) (DPN) was developed for the determination of adrenaline for the first time. The possible CL emission mechanism was briefly discussed by comparing the fluorescence emission spectra with CL spectra. Under the optimum conditions, the relative CL intensity was linear over the concentration of AD ranging from 1.0 × 10−7 to 1.0 × 10−5 g mL−1 with a detection limit of 4.0 × 10−8 g mL−1 (3σ). And the relative standard deviation was 3.7% for 2.0 × 10−6 g mL−1 AD (n = 11). The developed method has been successfully applied to the determination of AD in pharmaceutical preparations.
In this work, we report a new chemiluminescence (CL) reaction between adrenaline and diperiodatonickelate in alkaline medium. The possible CL emission mechanism was briefly discussed by comparing the fluorescence emission with CL spectra for the first time.Figure optionsDownload as PowerPoint slide
Journal: Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy - Volume 121, 5 March 2014, Pages 288–291