کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1273058 1497513 2013 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Low cost monitoring system for safe production of hydrogen from bio-ethanol
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
پیش نمایش صفحه اول مقاله
Low cost monitoring system for safe production of hydrogen from bio-ethanol
چکیده انگلیسی


• The monitoring system is based on the fault detectability index (FDI) using (PCA).
• The FDI predicts well the optimal number of measurements to detect critical faults.
• Integration between supervision and control guarantee safety conditions at lower cost.
• 15 types of faults in sensors, actuators, catalyzer and fuel cell are analyzed.
• Comparisons with other methodology are discussed.

In this paper a monitoring system is developed to guarantee safety operational conditions for the hydrogen production from bioethanol. The key idea is to detect the most critical faults with the minimum number of sensors. It can be done through a fault detectability index (FDI) which drives to the optimal measurements selection for building a proper monitoring system. The FDI calculation is based on principal component analysis (PCA) model with combined statistics. It takes into account those sensors already selected for control purposes and penalizes the use of new measurement devices. The overall methodology is tested for fifteen failures such as the catalyzer deterioration in the reforming reactor, faults at the fuel cell, sensors and actuators. Hence, the investment cost can be reduced drastically without losing quality of fault detection. The monitoring system with the selected sensors by the FDI performs better than using all the available plant measurements.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Hydrogen Energy - Volume 38, Issue 32, 25 October 2013, Pages 13872–13883
نویسندگان
, , ,