کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1279622 1497654 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Research of a HySyLab internal standard procedure for single PEMFC
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
پیش نمایش صفحه اول مقاله
Research of a HySyLab internal standard procedure for single PEMFC
چکیده انگلیسی

In literature there are many articles and documents discussing possible single PEMFC test protocols and some attempts to identify a good procedure to which conform, e.g. “single cell test protocol” (USFCC) or “PEFC testing procedures” (FCTESTNET). The Hydrogen System Laboratory (HySyLab) has identified an internal test protocol for a good PEMFC characterisation. In the paper the procedure is illustrated in all its aspects: the assembly, the conditioning and the characterisation of a single PEMFC through polarisation curves under different conditions of temperature, pressure and relative humidity. Other aspects like internal resistance and pressure drops are studied. The HySyLab procedure permits to obtain reproducible and excellent performances with commercial MEAs and PEMFCs tested in laboratory (2200mAcm-2 at 0.4 V at 70∘C cell temperature, 100%RH, ambient pressure, λair=2.5λair=2.5 and λH2=1.5λH2=1.5).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Hydrogen Energy - Volume 33, Issue 12, June 2008, Pages 3159–3166