کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1418917 986017 2005 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Graphite thermal expansion relationship for different temperature ranges
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
Graphite thermal expansion relationship for different temperature ranges
چکیده انگلیسی

For practical reasons, the coefficient of thermal expansion (CTE) has to be measured over a particular temperature range, for example 20–120 °C, 20–400 °C or 500–700 °C. However, in many cases, engineers or scientists involved in the assessment of graphite components such as nuclear reactor moderator bricks, electrodes or moulds require CTE over temperature ranges other than that of the original measurement. This paper compares three different techniques used to convert CTE from one temperature range to another. The method used by the UK nuclear industry is compared with techniques proposed by two international companies. There was close agreement between two of the methods. However there was some divergence in the case of the third method. This may be related to the type of graphite (fine-grain) for which the third method was developed.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Carbon - Volume 43, Issue 14, November 2005, Pages 2902–2906
نویسندگان
, , , ,