کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
153906 456543 2009 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Removal of cyanide from water and wastewater using granular activated carbon
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Removal of cyanide from water and wastewater using granular activated carbon
چکیده انگلیسی

Cyanide is used extensively in the electroplating and mining industries due to its strong affinity to metal cations. Commercial granular activated carbon (GAC) was used as adsorbent for the adsorptive study of sodium, zinc and iron, cyanide complexes in the present study. The effect of process parameters such as pH, temperature, adsorbent size and dose, contact time on the performance of adsorption was investigated. Optimum pH was found to be 9, 7 and 5 for sodium, zinc and iron cyanides respectively. In the higher temperature range more percentage removal was observed for iron cyanides, whereas, sodium and zinc cyanides were removed optimally at 25–35 °C. Although particle size did not show any major influence on the percentage removal, but optimum size was taken as 2–4 mm. The percentage removal of cyanide compounds increased with the increase in adsorbent (GAC) concentration. However, specific uptake did not increase at GAC concentration above 20–25 g/L. Hence 20 g/L was considered as the optimum dose of adsorbent. Higher removal efficiency was achieved for metal cyanides as compared to sodium cyanide at optimal conditions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemical Engineering Journal - Volume 146, Issue 3, 15 February 2009, Pages 408–413
نویسندگان
, , ,