کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1564895 999777 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of specimen thickness on DHC velocity for Zr-2.5Nb alloy pressure tube material
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی هسته ای و مهندسی
پیش نمایش صفحه اول مقاله
Effect of specimen thickness on DHC velocity for Zr-2.5Nb alloy pressure tube material
چکیده انگلیسی
Zr-2.5Nb alloy pressure tubes used in pressurized heavy water reactors (PHWR) are susceptible to failure by Delayed Hydride Cracking (DHC), which is a form of localized hydride-embrittlement phenomenon manifested in the presence of a hydrostatic stress gradient and hydrogen concentration above a threshold limit as a sub-critical crack growth process in hydride forming metals. The DHC parameters used for safety assessment are DHC velocity (VDHC) and a threshold stress intensity factor (KIH). In this work DHC velocity was determined for Zr-2.5Nb pressure tube material at 250 and 280 °C using specimens of thickness between 1 mm and 4.5 mm. The DHC velocity was found to increase with increase in specimen thickness at 250 °C and 280 °C. Significant amount of tunneling of the crack was observed for 1-mm and 2-mm thick specimens at 250 °C and 280 °C, with the degree of tunneling increasing with decrease in thickness and increase in test temperature.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Nuclear Materials - Volume 467, Part 1, December 2015, Pages 373-382
نویسندگان
, , , , ,