کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1568768 1514251 2008 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Rupture pressure of wear degraded alloy 600 steam generator tubings
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی هسته ای و مهندسی
پیش نمایش صفحه اول مقاله
Rupture pressure of wear degraded alloy 600 steam generator tubings
چکیده انگلیسی

Fretting/wear degradation at the tube support in the U-bend region of a steam generator (SG) of a pressurized water reactor (PWR) has been reported. Simulated fretted flaws were machined on SG tubes of 195 mm in length. A pressure test was carried out with the tubes at room temperature by using a high pressure test facility which consisted of a water pressurizing pump, a test specimen section and a control unit. Water leak rates just after a ligament rupture or a burst were measured. Tubes degraded by up to 70% of the tube wall thickness (TW) showed a high safety margin in terms of the burst pressure during normal operating conditions. Tubes degraded by up to 50% of the TW did not show burst. Burst pressure depended on the defect depths rather than on the wrap angles. The tube with a wrap angle of 0° showed a fish mouth fracture, whereas the tube with a 45° wrap angle showed a three way fracture.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Nuclear Materials - Volume 373, Issues 1–3, 15 February 2008, Pages 71–74
نویسندگان
, , , , ,