کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1569482 | 1514258 | 2007 | 5 صفحه PDF | دانلود رایگان |

The systems registering plasma radiation comprise optical elements, which may distort a diagnostic signal if they are not radiation resistant. The work was aimed at experimental study of optical absorption and γ-induced luminescence of KU-1 quartz glass and sapphire crystals in the range of 200–900 nm, which were irradiated in the 60Co γ-ray source of 6.7 Gy s−1 up to the dose of 108 Gy and in the water cooled nuclear reactor of WWR-SM type with neutron fluences of 1017–1020 cm−2, in order to imitate plasma effect. The transparency window (minimal optical losses) and the intrinsic luminescence bands were determined in the studied materials. The advantages of KU-1 type glass over sapphire as optical elements at 300–350 K have been demonstrated.
Journal: Journal of Nuclear Materials - Volume 362, Issues 2–3, 31 May 2007, Pages 222–226