On the (in)adequacy of the Charpy impact test to monitor irradiation effects of ferritic/martensitic steels
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی هسته ای و مهندسی
پیش نمایش صفحه اول مقاله
On the (in)adequacy of the Charpy impact test to monitor irradiation effects of ferritic/martensitic steels
چکیده انگلیسی

Irradiation embrittlement studies rely very often on Charpy impact data, in particular the ductile-to-brittle transition temperature (DBTT). However, while the DBTT-shift is equivalent to the increase of the fracture toughness transition temperature of ferritic steels, it is not the case for ferritic/martensitic steels. The aim of this study is to critically assess experimental data obtained on a 9%Cr–ferritic/martensitic steel, Eurofer-97, to better understand the underlying mechanisms involved during the fracture process. More specifically, a dedicated analysis using the load diagram approach allows to unambiguously reveal the actual effects of irradiation on physically rather than empirically based parameters. A comparison is made between a ferritic and ferritic/martensitic steel to better identify the possible similarities and differences. Tensile, Charpy impact and fracture toughness tests data are examined in a global approach to assess the actual rather than apparent irradiation effects. The adequacy or inadequacy of the Charpy impact test to monitor irradiation effects is extensively discussed.