کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1727899 | 1521105 | 2016 | 7 صفحه PDF | دانلود رایگان |
In order to meet clean core challenges in Sodium-Cooled Fast Reactors (SFR), specific attention is paid to the cladding integrity. To monitor this integrity, Delayed Neutron Detection (DND) systems are implemented. During clad failures, neutron precursor fission products (mainly halogens: 137I, 87Br, 88Br) escape into the primary coolant. The detection of these precursors through their delayed neutron emission ensures a diagnosis on clad failures events. In DND systems, 3He proportional counters are selected as the best available technology for neutron detection purposes. Associated with 3He counters, polyethylene blankets are required in order to thermalize neutrons. The first part of this study is dedicated to the optimization of the DND device by Monte-Carlo simulations in order to improve the detection capability. This optimization focuses on the device design presenting a graphite based alternative to polyethylene blankets in order to remove photoneutron noise from 2D(γ,n) reactions in polyethylene in presence of a high 24Na activity (emission of gamma rays at 2.75 MeV). The experimental part of this study is devoted to the validation of a measuring station including an 3He counter with carbon for neutron moderation. Both Monte-Carlo simulations and experimental results highlight the potential for a low-noise DND system based on graphite moderation.
Journal: Annals of Nuclear Energy - Volume 92, June 2016, Pages 440–446