In this paper, exergy method is applied to analyze the ejector expansion Joule–Thomson (EJT) cryogenic refrigeration cycle. The exergy destruction rate in each component of the EJT cycle is evaluated in detail. The effect of some main parameters on the exergy destruction and exergetic efficiency of the cycle is also investigated. The most significant exergy destruction rates in the cycle are in the compressor and ejector. The ejector pressure ratio and compressor isothermal efficiency have a significant effect on the exergetic efficiency of the EJT cycle. The exergy analysis results show the EJT cycle has an obvious increase in the exergetic efficiency compared to the basic Joule–Thomson refrigeration cycle. A significant advantage from the use of the ejector is that the total exergy destruction of the EJT cycle can be reduced due to much more decreasing of the exergy destruction rates in the compressor and expansion valve. The exergy analysis also reconfirms that applying an ejector is a very important approach to improve the performance of the Joule–Thomson cryogenic refrigeration cycle.