کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1755393 1522842 2012 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Leakage characterization through above-zone pressure monitoring: 2—Design considerations with application to CO2 storage in saline aquifers
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات زمین شناسی اقتصادی
پیش نمایش صفحه اول مقاله
Leakage characterization through above-zone pressure monitoring: 2—Design considerations with application to CO2 storage in saline aquifers
چکیده انگلیسی

Deep saline aquifers are widely used for waste disposal and are the main candidates for storage of CO2 as a means of reducing greenhouse gas emissions to the atmosphere. Safety of disposal/storage projects highly depends on the containment of CO2 within the target aquifer. However, since the cap-rock overlying the aquifer may include leakage pathways that permit the injected fluids to leak to subsurface formations and/or to surface, detection and characterization of any such pathways from storage formations into overlying formations are required. A leakage test has been introduced in an earlier paper to characterize a leakage pathway through pressure monitoring in an overlying aquifer separated from the target aquifer by the cap-rock. A leakage pathway can be characterized by the leak transmissibility and location parameters, so a successful test should be able to provide sufficient confidence to evaluate the transmissibility and location parameters. In this work, different strategies are evaluated in order to achieve a successful test. The strategies include increasing the sampling frequency, use of pulsing, and increasing the number of monitoring/injection wells. The information provided by different strategies is evaluated, based on their effects on well-posing the inverse problem. The effects are studied based on information and correlation matrices, as well as the confidence interval. Locating the monitoring well is studied considering the requirements to ensure the safety of CO2 storage projects. Finally, we present a graphical method to obtain prior information on the leak based on the pressure derivative data. The graphical method is obtained based on deriving a new real-time analytical solution for the pressure at the monitoring zone.


► Strategies to enhance leak characterization through above-zone pressure monitoring are studied.
► The value of information provided by each strategy is assessed.
► Placement of monitoring wells is discussed considering requirements of CO2 storage applications.
► A graphical method is introduced to obtain leak parameters using a function of pressure derivative.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Petroleum Science and Engineering - Volumes 98–99, November 2012, Pages 69–82
نویسندگان
, ,