Effects of reactor height/diameter ratios ranged from 24 to 4 corresponding to reactor settling velocities from 12 to 2 m h−1 on aerobic granulation were investigated. It was found that granules appeared after 1-week operation and granule volume percentages exceeded 50% after 2–3 weeks in four reactors. In addition, similar granule fraction of 94–96% was found at steady state in all four reactors. Sludge volume index (SVI), average sludge size, biomass density and granule settling velocity at steady state were around 50 ml g−1, 1800 μm, 53 g l−1 and 40 m h−1, respectively, in four reactors. Extracellular polymeric substances (EPS) and specific oxygen uptake rate (SOUR) were around 38 mg g−1 VSS and 40 mg O2 g−1 VSS h−1, respectively. Denaturing gradient gel electrophoresis (DGGE) fingerprint of sludge in four reactors showed the same microbial population shift during the start-up period and same microbial community structure during steady-state period. These results recommended strongly that reactor height/diameter ratio or reactor setting velocity in the used range in this study did not affect granule formation, physical characteristics, microbial community structure of granules and stable operation of granular sludge reactor. Reactor height/diameter ratio thus can be very flexible in the practice, which is important for the application of aerobic granule technology.
Journal: Enzyme and Microbial Technology - Volume 45, Issue 5, 5 November 2009, Pages 379–383