کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1812172 1025609 2010 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Reanalysis of energy levels and crystal field parameters for Er3+ and Tm3+ ions at C2 symmetry sites in hexahydrated trichloride crystals—Intricate aspects of multiple solutions for monoclinic symmetry
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم فیزیک ماده چگال
پیش نمایش صفحه اول مقاله
Reanalysis of energy levels and crystal field parameters for Er3+ and Tm3+ ions at C2 symmetry sites in hexahydrated trichloride crystals—Intricate aspects of multiple solutions for monoclinic symmetry
چکیده انگلیسی

Crystal-field splittings of lanthanide Ln3+ (Ln=Er, Tm) ions in hexahydrated Ln-trichlorides LnCl3·6H2O are re-analyzed in order to obtain consistent and standardized crystal-field parameter (CFP) sets. Experimental energy levels obtained by others were fitted to Hamiltonian parameters representing the combined free-ion and crystal-field interactions for Er3+ and Tm3+ ions in the actual monoclinic C2 symmetry sites. The reliable starting values of the CFPs were obtained from superposition model calculations. Analysis of multiple solutions with relatively low r.m.s. deviation poses a dilemma arising from intricate aspects of fitted CFPs for low site symmetry systems. In order to solve this dilemma we propose a comprehensive procedure consisting in (i) model calculations of CFPs, (ii) scanning of the CF parameter space using values of the starting 2nd-rank CFPs in reasonable ranges, (iii) using starting CFP sets located in different regions of the CF parameter space for fittings, (iv) considering the effect of sign changes in CFPs on the fitted solutions, and (v) comparative analysis of the transformation properties of all fitted CFP sets based on the monoclinic standardization approach and the multiple correlated fitting technique. An important finding is that some of the multiple and seemingly comparable solutions for fitted CFP sets turn out to be spurious solutions. The nature of these computer artifacts is elucidated. Such artifacts occur when the descent in symmetry method is applied for initial evaluation of the starting CFPs, while the approximated higher symmetry axes do not coincide with the actual symmetry axes. Wider applications of the proposed procedure in CF studies of low site symmetry systems may improve the reliability of the CFP sets reported in literature.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physica B: Condensed Matter - Volume 405, Issue 7, 1 April 2010, Pages 1927–1940
نویسندگان
, , ,