کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1820574 1525786 2006 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Test of the photocathode cooling system of the 312 cell SRF gun
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم فیزیک ماده چگال
پیش نمایش صفحه اول مقاله
Test of the photocathode cooling system of the 312 cell SRF gun
چکیده انگلیسی
This paper presents results of the photocathode cooling system test of the 312 cell SRF gun at the Forschungszentrum Rossendorf. The SRF gun will produce short electron pulses with high bunch charges and low transverse emittance. The requirement for the superconducting electron linear accelerator in Rossendorf (ELBE) is to provide a low emittance electron beam up to 1 mA current and 9.5 MeV energy. Additionally, it will easily operate in continuous wave (cw) mode because of the low RF power losses in the superconducting material. Therefore, the normal conducting copper cathode must be cooled by liquid nitrogen in order to preserve the temperature of the cavity at 2.2 K. The estimated power input from the RF field into the cathode could be more than 10 W [P. vom Stein, Thesis, TU-Dresden, 1998]. First results of temperature measurements of the photocathode, respectively, from the cooling system at a heat load up to 30 W are presented.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physica C: Superconductivity - Volume 441, Issues 1–2, 15 July 2006, Pages 216-219
نویسندگان
, , , , , , , , , , , , , , , , ,