Resumption of JRR-4 and characteristics of neutron beam for BNCT
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Resumption of JRR-4 and characteristics of neutron beam for BNCT
چکیده انگلیسی

The clinical trials of Boron Neutron Capture Therapy (BNCT) have been conducted using Japan Research Reactor No. 4 (JRR-4) at Japan Atomic Energy Agency (JAEA). On December 28th, 2007, a crack of a graphite reflector in the reactor core was found on the weld of the aluminum cladding. For this reason, specifications of graphite reflectors were renewed; dimensions of the graphite were reduced and gaps of water were increased. All existing graphite reflectors of JRR-4 were replaced by new graphite reflectors. In February 2010 the resumption of JRR-4 was carried out with new graphite reflectors. We measured the characteristics of neutron beam at the JRR-4 Neutron Beam Facility. A cylindrical water phantom of 18.6 cm diameter and 24 cm depth was set in front of the beam port with 1 cm gap. TLDs and gold wires were inserted within the phantom when the phantom was irradiated. The results of the measured thermal neutron flux and the gamma dose in water were compared with that of MCNP calculation. The neutron energy spectrum of the calculation model with new reflector had little variation compared to that with old reflector, but intensities of the neutron flux and gamma dose with new reflector were rather smaller than those with old reflector. The calculated results showed the same tendency as that of the experimental results. Therefore, the clinical trials of BNCT in JRR-4 could be restarted.


► Crack of a graphite reflector in the reactor core was found on the weld of the aluminum cladding.
► Resumption of JRR-4 was carried out with new graphite reflectors.
► Measurement of the characteristics of neutron beam at the JRR-4 Neutron Beam Facility.
► The new graphite reflector has little effect, compared to the old reflector, on the obtained neutron spectrum.
► Neutron fluxes calculated by MCNP with the new graphite reflector relatively decreased by approximately 8%.