کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1891672 1043909 2011 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis of dose distribution changes in radiation processing using a continuous variable F-test and p-value
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Analysis of dose distribution changes in radiation processing using a continuous variable F-test and p-value
چکیده انگلیسی
A process monitoring practice is established from the evaluation of dose distribution within simulant or phantom materials. As a part of change control, an evaluation of potential changes to dose distribution is conducted when change activities occur to the irradiator. (AAMI/AAMI/ISO 11137-1, 2006) The dose distribution evaluation is conducted to verify either the continued validity of an established process monitoring practice or demonstrate that the monitoring practice is no longer valid. Historically, change control evaluation of a process monitoring practice has been based on a non-statistical evaluation of dose distribution data for potential change. A statistical method has been developed using a continuous variable F-test and p-value, which tests a null hypothesis of no change in dose distribution, and provides a means of either substantiating or refuting the continued validity of a process monitoring practice.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Radiation Physics and Chemistry - Volume 80, Issue 6, June 2011, Pages 755-760
نویسندگان
,