BackgroundA novel method has been developed for the determination of free warfarin in human plasma by ultra performance liquid chromatography combined with tandem mass spectrometry (UPLC–MS/MS).MethodsThe plasma filtrate was prepared by a high-speed ultrafiltration (UF), and was then extracted by a liquid/liquid extraction (LLE) with ethyl acetate. The chromatographic separation was performed on an Acquity UPLC™ BEH C18 (2.1 mm × 50 mm, 1.7 μm, Waters) with a mobile phase consisting of 0.1% formic acid/acetonitrile (50:50, v/v). The analyses were carried out by multiple reaction monitoring (MRM) using the precursor-to-product combinations of m/z 307.3→161.2 for warfarin and m/z 347.2→161.3 for Cl-War.ResultsThe lower limit of quantification (LLOQ) was 0.25 ng/ml and the assay exhibited a linear range of 0.25–16 ng/ml and gave a correlation coefficient (r) of ≥ 0.9999. Quality control samples (0.5, 2, 8 ng/ml) in 5 replicates from 3 different runs of analysis demonstrated intra-assay CVs of 3.0–10.2%, inter-assay CVs of 4.2–12.0%, and an overall accuracy of 85–115%.ConclusionsThe method can be applied to analyze the correlation of free concentration of warfarin and the international normalized ratio (INR).
Journal: Clinica Chimica Acta - Volume 393, Issue 2, 17 July 2008, Pages 85–89