کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
1971452 | 1059857 | 2009 | 7 صفحه PDF | دانلود رایگان |

ObjectivesTo develop a rapid convenient-to-implement high performance liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for determination of serum testosterone concentration in routine clinical laboratories.MethodsFollowing extraction by organic solvents, an Agilent 1200 Series HPLC system coupled to an API 5000 mass spectrometer equipped with an atmospheric pressure chemical ionization ion source was used to separate, detect and quantify serum testosterone. Ion-transitions of m/z 289.2 → 109.1 and 294.2 → 113.2 were used to monitor testosterone and testosterone-2,2,4,6,6-d5, respectively.ResultsFunctional sensitivity was 0.056 nmol/L (CV 20%). Within-run and total imprecision were 4.6% and 5.2% at 1.3 nmol/L, 2.4% and 4.3% at 11.0 nmol/L, and 1.9% and 1.9% at 23.4 nmol/L respectively. The LC-MS/MS method agreed closely with three automated immunoassays when the concentration of testosterone exceeded 3 nmol/L. However, the immunoassays showed a positive bias at concentrations below 3 nmol/L.ConclusionThis method provides a rapid, simple, highly selective and sensitive procedure that can be easily used for determination of serum testosterone in routine clinical laboratories. It measures serum testosterone precisely and accurately at concentrations found in children and adults of both genders.
Journal: Clinical Biochemistry - Volume 42, Issue 6, April 2009, Pages 484–490