کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1991272 1540992 2016 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Diagnosis of 21-hydroxylase deficiency by urinary metabolite ratios using gas chromatography–mass spectrometry analysis: Reference values for neonates and infants
ترجمه فارسی عنوان
تشخیص کمبود 21 هیدروکسیلاز با نسبت متابولیت های ادرار با استفاده از تجزیه و تحلیل جرم کروماتوگرافی گاز: مقادیر مرجع برای نوزادان و نوزادان
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی زیست شیمی
چکیده انگلیسی


• One major issue ofnewborn screening for congenital adrenal hyperplasia due to 21-hydroxylase deficiency (21OHD) is the high false-positive rate, especially in preterm neonates.
• Urinary steroid metabolite analysis using gas chromatography–mass spectrometry (GC–MS) is suitable as a confirmatory diagnostic tool.
• We have developed reference values for diagnostic urinary steroid metabolite ratios in a large cohort of neonates and infants with 21OHD.
• The best diagnostic ratio for 21OHD was pregnanetriolone to 6α-hydroxy-tetrahydrocortisone.

One major issue of newborn screening programs for 21-hydroxylase deficiency (21OHD) is the high rate of false-positive results, especially in preterm neonates. Urinary steroid metabolite analysis using gas chromatography–mass spectrometry (GC–MS) is suitable as a confirmatory diagnostic tool.The objective of this study was to analyze retrospectively diagnostic metabolite ratios in neonates and infants with and without 21OHD using GC–MS with emphasis on glucocorticoid metabolism, and to develop reference values for the steroid metabolite ratios for the diagnosis of 21OHD.We retrospectively analyzed urinary steroid hormone metabolites determined by GC–MS of 95 untreated neonates and infants with 21OHD (1–148 days), and 261 neonates and infants (100 preterms) without 21OHD (0–217 days).Metabolites of 17α-hydroxyprogesterone showed specificities below 98%, whereas the 21-deoxycortisol metabolite pregnanetriolone clearly separated 21OHD from non-21OHD subjects. The best diagnostic ratio for 21OHD was pregnanetriolone to 6α-hydroxy-tetrahydrocortisone. The lowest value of this ratio in the 21OHD group (0.47) was at least eight times higher than the highest values in the non-21OHD group (0.055).We have given appropriate reference values for steroid metabolite ratios in the largest 21OHD cohort so far described. Consideration of glucocorticoid metabolism, especially the use of typical neonatal 6α-hydroxylates metabolites, leads to improvement of diagnostic metabolite ratios.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Steroid Biochemistry and Molecular Biology - Volume 156, February 2016, Pages 10–16
نویسندگان
, , , , ,