کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1994954 1064941 2011 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison between laser speckle contrast imaging and laser Doppler imaging to assess skin blood flow in humans
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی زیست شیمی
پیش نمایش صفحه اول مقاله
Comparison between laser speckle contrast imaging and laser Doppler imaging to assess skin blood flow in humans
چکیده انگلیسی

ObjectiveWe tested the linearity between skin blood flux recorded with laser speckle contrast imaging (LSCI) and laser Doppler imaging (LDI), comparing different ways of expressing data. A secondary objective was to test within-subject variability of baseline flux with the two techniques.MethodsWe performed local heating at 36, 39, 42, and 44 °C on the forearm of healthy volunteers, and measured cutaneous blood flux with LDI and LSCI. Biological zero (BZ) was obtained by occluding the brachial artery. We expressed data as raw arbitrary perfusion units (APUs) and as a percentage increase from baseline (%BL), with and without subtracting BZ. Inter-site variability was expressed as a within subject coefficient of variation (CV).ResultsTwelve participants were enrolled. Inter-site variability at baseline was lower with LSCI (CV = 9.2%) than with LDI (CV = 20.7%). We observed an excellent correlation between both techniques when data were expressed as raw APUs or APU − BZ (R = 0.90; p < 0.001). The correlation remained correct for %BL (R = 0.77, p < 0.001), but decreased for %BL − BZ (R = 0.44, p = 0.003). Bland–Altman plots revealed a major proportional bias between the two techniques.ConclusionThis study suggests that skin blood flux measured with LSCI is linearly related to the LDI signal over a wide range of perfusion. Subtracting BZ does not affect this linearity but introduces variability in baseline flux, thus decreasing the correlation when data are expressed as a function of baseline. Finally, systematic bias makes it impossible to assimilate arbitrary perfusion units provided by the two systems.

Figure optionsDownload as PowerPoint slideHighlights
► There is an excellent correlation between LSCI and LDI over a wide range of perfusion.
► Biological zero should not be subtracted when expressing data as a function of baseline.
► There is a systematic bias making comparison between the two techniques impossible.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microvascular Research - Volume 82, Issue 2, September 2011, Pages 147–151
نویسندگان
, , , ,