کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
217939 463175 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Amperometric sensing of sodium, calcium and potassium in biological fluids using a microhole supported liquid/gel interface
ترجمه فارسی عنوان
سنجش آمپورتومتر سدیم، کلسیم و پتاسیم در مایعات بیولوژیکی با استفاده از رابط مایع / ژل پشتیبانی شده از میکرو حفره
کلمات کلیدی
انتقال یون تسهیل شده حسگر آمپر، رابط میکرو مایع / ژل، کاتیون ها، یونوفورس
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
چکیده انگلیسی


• A single microhole-water/organic gel interface platform for the amperometric detection of Na+, Ca2 + and K+ ions.
• Assisted transfer reaction of Na+, Ca2 + and K+ by dibenzo-18-crown-6, calcium ionophore II and valinomycin, respectively.
• Quantitative analysis of native concentrations of Na+, Ca2 + and K+ ion in serum and plasma samples.
• Validation of the sensors performance for Na+, Ca2 + and K+ ion analysis with inductively coupled plasma mass spectrometry.
• Good detection limit with a linear dynamic range from 5 μM to 100 μM for Na+, Ca2 + and K+ ions.

In this paper, we successfully applied a cost-effective and simple amperometric sensing design featuring a single microhole-water/organic gel interface to determine native sodium, calcium and potassium ion concentrations in biological fluids. The detection was based on measuring current changes associated with the transfer of each cation type across a microhole supported water/polyvinylchloride-2-nitrophenyl octylether gel interface. Three different sensing platforms were applied to the same biological sample with each only differing in the selective ionophore incorporated into the organic phase: dibenzo-18-crown-6 for sodium, calcium ionophore II (ETH 129) for calcium and valinomycin for potassium ions. Assisted transfer reactions of each ion from the aqueous to the organic gel layer by the corresponding ionophores were first characterized using cyclic voltammetry and then further analyzed using differential pulse stripping voltammetry. A linear dynamic range from 5 μM to 100 μM was achieved for each ion target. This enabled quantitative measurements of native concentrations of Na+, Ca2 + and K+ in biological fluid samples including serum and plasma. The amperometric measurements were also validated by comparing with inductively coupled plasma mass spectrometry.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electroanalytical Chemistry - Volume 769, 15 May 2016, Pages 5–10
نویسندگان
, ,