Fabrication of an electrochemical molecularly imprinted polymer triamterene sensor based on multivariate optimization using multi-walled carbon nanotubes
چکیده انگلیسی


• The computational method was applied to screening functional monomers of MIP.
• Experimental design for optimization was carried out.
• A Tr-imprinted sensor was fabricated by electropolymerizing of pyrrole.
• The sensor was used to analysis of Tr in serum and pharmaceutical samples.

A novel electrochemical sensor using molecularly imprinted polymer (MIP) technique for the detection of triamterene (Tr) was developed. A computational approach was used for screening functional monomers and polymerization solvent in the rational design of MIPs. Based on computational results, the binding capacity showed that the highest binding specificity toward Tr could achieved when using pyrrole (PY) as the monomer in dimethyl sulfoxide (DMSO) solution to form a polymer matrix. The sensitive MIP sensor for Tr was electrochemically synthesized onto multi-walled carbon nanotubes immobilized pencil graphite electrode (MWCNTs/PGE) surface. The multivariate methods were used to optimize the voltammetric response of modified electrode for determination of Tr. A Plackett–Burman design (PBD) was chosen as a screening method to estimate the relative influence of the factors that could have an influence on the analytical response (current). The significant variables were optimized using central composite design (CCD). Under the optimized conditions, the calibration curve demonstrated linearity over a concentration range of 0.08–265 μM of Tr with R2 = 0.9909. The detection limit of Tr was obtained 3.35 nM (3sb, n = 7). The sensor showed a good reproducibility and regeneration capacity. The relative standard deviation (RSD%) of 3.99% was obtained to evaluate of electrode-to electrode reproducibility. This sensor was successfully applied to the quantification of Tr in some serum and pharmaceutical samples.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electroanalytical Chemistry - Volume 744, 1 May 2015, Pages 85–94
نویسندگان
, ,