• A new voltammetric signal was used in ultra trace analysis.
• An environmentally friendly electrode was used for fenoxanil determination.
• The new application of an Hg(Ag)FE for the reduction of nitrile is presented.
A new, simple, and highly sensitive voltammetric method for the determination of low concentrations of a novel fungicide, fenoxanil (Fen), was developed using square wave voltammetry (SWV) and square wave adsorptive stripping voltammetry (SWAdSV) on a renewable silver amalgam film electrode (Hg(Ag)FE). The electrochemical reduction of Fen at the Hg(Ag)FE in Britton-Robinson (B-R) buffer at pH 6.8 was studied for the first time. The effect of the supporting electrolyte, pH, conditioning potential and conditioning time, frequency, amplitude, step potential, and accumulation potential and accumulation time were studied to select the optimum experimental conditions. The developed method can determine Fen in the concentration range of 5 × 10−7–4 × 10−6 mol L−1 for SWV and 1 × 10−10–9 × 10−10 mol L−1 for SWAdSV. Validation of the method was carried out. The method was successfully applied for trace level determination of Fen in spiked Warta River water and spiked rice samples by the standard addition method. The interference of common agents and metal ions was also examined. Fen adsorption at the mercury electrode was studied.
Figure optionsDownload as PowerPoint slide
Journal: Journal of Electroanalytical Chemistry - Volume 738, 1 February 2015, Pages 69–76