کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
221499 463402 2006 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Highly sensitive electrogenerated chemiluminescence (ECL) method for famotidine with pre-anodizing technique to improve ECL reaction microenvironment at graphite electrode surface
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
پیش نمایش صفحه اول مقاله
Highly sensitive electrogenerated chemiluminescence (ECL) method for famotidine with pre-anodizing technique to improve ECL reaction microenvironment at graphite electrode surface
چکیده انگلیسی

In this paper, it was found that, compared to the modification of the graphite electrode with carboxyl-based multi-walled carbon nanotubes, the pre-anodized graphite electrode prepared by electrochemical method, not only still owned the pre-concentrating effect for famotidine, but also created a suitable electrogenerated chemiluminescence (ECL) reaction microenvironment to improve the enhancing ECL effect of the famotidine on electro-oxidation of Ru(bpy)32+. Based on these findings, a new ECL method for famotidine was developed. Under the optimum experimental conditions, this new ECL method offered a 1.9 × 10−10 g/mL detection limit for famotidine and the enhancing ECL signal was linear with famotidine concentration in the range of 1.0 × 10−9–1.0 × 10−6 g/mL. The presented method was successfully used to detect famotidine in plasma samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electroanalytical Chemistry - Volume 587, Issue 1, 1 February 2006, Pages 161–168
نویسندگان
, ,