کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2549063 1124496 2014 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Comparison of freely-moving telemetry Chinese Miniature Experiment Pigs (CMEPs) to beagle dogs in cardiovascular safety pharmacology studies
موضوعات مرتبط
علوم پزشکی و سلامت داروسازی، سم شناسی و علوم دارویی داروشناسی
پیش نمایش صفحه اول مقاله
Comparison of freely-moving telemetry Chinese Miniature Experiment Pigs (CMEPs) to beagle dogs in cardiovascular safety pharmacology studies
چکیده انگلیسی

IntroductionTelemetry beagle dogs are the most frequently used species in cardiovascular telemetry assessments. However, beagle dogs may not be always suitable for all of the tests. Recently minipigs have received increased attention for these studies. Differences between the two species regarding the response of their cardiovascular systems to environmental stimuli are unclear. This study investigates how the telemetry minipig compares to beagle dog as a test subject and also refines the experimental protocols necessary to obtain accurate data.MethodsBeagle dogs and Chinese Miniature Experiment Pigs (CMEPs) were implanted with telemetry transmitters and the influences of gavage, feeding and the circadian cycle on various cardiovascular parameters were investigated.ResultsECG signal quality from CMEPs was superior to that of the beagle dogs. Poor ECG signal quality, elevated HR, BP and locomotor activity associated with gavage and feeding were observed in both species. ECG signal quality, BP and locomotor activity recovered more quickly in the CMEPs than in the beagle dogs. Residual elevation of HR found in CMEPs lasted approximately 4 h post-feeding, which has a profound influence on the circadian cycle. A diurnal rhythm in CMEP with a significant increase of body temperature during the dark period and a clear circadian rhythm of locomotor activity in both species were observed.DiscussionThe present data demonstrated that gavage, feeding and circadian cycle were having an enormous influence on BP, HR and locomotor activity in both species. If drug-induced effects are expected rapidly after oral administration and feeding, CMEP seems to be a favorable choice. Also, due to the effects of feeding on HR, CMEPs should fast at least 5 h before the start of recording or should not be fed during the study where the Tmax of a given compound might occur very late. It also should be taken into consideration when the test article has a potential effect on body temperature by using CMEPs. In summary, the telemetry CMEP is a valuable alternative to the beagle dog for cardiovascular telemetry studies.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmacological and Toxicological Methods - Volume 70, Issue 1, July–August 2014, Pages 19–28
نویسندگان
, , , , , , , , , , , , , , ,