کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2550121 1124539 2009 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
QA interval as an indirect measure of cardiac contractility in the conscious telemeterised rat: Model optimisation and evaluation
موضوعات مرتبط
علوم پزشکی و سلامت داروسازی، سم شناسی و علوم دارویی داروشناسی
پیش نمایش صفحه اول مقاله
QA interval as an indirect measure of cardiac contractility in the conscious telemeterised rat: Model optimisation and evaluation
چکیده انگلیسی

IntroductionConscious telemeterised rats are used for early assessment of cardiovascular drug safety. This paper details the surgery required to allow key cardiovascular parameters to be determined and describes how QA interval (QAI), a surrogate measure of cardiac contractility, is related to a more direct measure of cardiac contractility, dP/dtmax (LVdP/dtmax). Experimental studies examining the effect of both positive and negative inotropes are described.MethodsEight rats were surgically implanted with telemetry probes for measuring blood pressure, heart rate, activity, body temperature and ECG parameters. Initial studies focussed on evaluating surgical procedures aimed at improving the ECG signal to allow QAI quantification. Once achieved, experimental studies were undertaken with verapamil, salmeterol, milrinone or vehicle. Following treatment, data was collected for ~ 20 h from pair-housed animals to establish effects on QAI or LVdP/dtmax, which was measured directly from the left ventricle in a separate group of rats.ResultsThe modified ECG lead placement produced both a qualitative and quantitative improvement in ECGs. Increases in cardiac contractility (measured directly) were paralleled by a decrease in QAI (measured indirectly). Salmeterol and milrinone increased (all p < 0.05) LVdP/dtmax (1942 ± 452 and 2333 ± 506 mmHg/s, respectively) and decreased QAI (3.5 ± 0.54 and 2.9 ± 0.43 ms, respectively). In contrast, the negative inotrope verapamil decreased LVdP/dtmax (–2119 ± 300 mmHg/s) and increased QAI (4.9 ± 0.46 ms). A statistically significant (p < 0.001) linear relationship was identified between log10(QAI) and log10(LVdP/dtmax).DiscussionImprovements in ECG signal quality, resulting from refinements in surgical techniques allowed for the reliable quantification of ECG parameters. The linear relationship demonstrated between log10(QAI) and log10(LVdP/dtmax) indicates that QAI may be a useful index of cardiac contractility in routine rat cardiovascular safety studies. These limited studies support the use of QAI as an indirect measure of cardiac contractility in the rat.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmacological and Toxicological Methods - Volume 60, Issue 2, September–October 2009, Pages 159–166
نویسندگان
, , , , , ,