کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
270219 | 504739 | 2009 | 12 صفحه PDF | دانلود رایگان |

Four full-scale reinforced concrete (RC) columns with L-shaped cross-sections, four full-scale RC columns with T-shaped cross-sections, three full-scale RC columns with +-shaped cross-sections, and one full-scale RC column with a square cross-section were experimentally investigated for fire resistance following the ISO834 standard heating process. The effects of axial load ratio and fire exposure condition on failure mode, axial deformation and fire resistance of the columns were analyzed. The experimental results showed that: (a) when the axial load ratio is 0.55, the fire resistances of the columns with L-, T-, and +-shaped cross-sections subjected to fire on all sides were 60–73% that of the column with the square cross-section. (b) In the case of samples subjected to fire on all sides, the fire resistance of columns with differently-shaped cross-sections increased in the following order: L-shaped cross-section
Journal: Fire Safety Journal - Volume 44, Issue 6, August 2009, Pages 869–880