An alternative method for fire smoke toxicity assessment using human lung cells
چکیده انگلیسی

An alternative method for fire smoke toxicity testing using human lung cells has been investigated. A laboratory-scale vertical tube furnace was used for the generation of combustion products. Experiments were conducted under isothermal oxidative non-flaming conditions. A range of building and train interiors including polyethylene (PE), polypropylene (PP), polycarbonate (PC), polyvinyl chloride (PVC), fiberglass reinforced polymer (FRP), and melamine-faced plywood (MFP) were studied. The exposure of combustion toxicants to human lung cells (A549) at the air/liquid interface was acquired using a Harvard Navicyte Chamber. Cytotoxic effects on human cells were assessed based on cell viability using the MTS assay (Promega). Cytotoxicity results were expressed as NOAEC (No Observable Adverse Effect Concentration), IC10 (10% inhibitory concentration), IC50 (50% inhibitory concentration) and total lethal concentration (TLC) values (mg/L). These cytotoxicity results were compared to published combustion toxicity data. Mass loss data and toxic product yield were also determined. The following toxicity ranking was observed from the most toxic to the least toxic: PVC>PE>PP> FRP-10>PC> FRP-16>MFP. The method described here could potentially be an alternative to current fire toxicity standard test methods.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fire Safety Journal - Volume 41, Issue 8, November 2006, Pages 605–615
نویسندگان
, , , ,