کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
271779 505006 2013 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Corrosion and activation analysis of the LIPAC beam dump cooling circuit
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
پیش نمایش صفحه اول مقاله
Corrosion and activation analysis of the LIPAC beam dump cooling circuit
چکیده انگلیسی

The LIPAC beam dump cooling circuit has been modelled by means of TRACT (TRansport and ACTivation) code. TRACT simulates the flow and isotope transport inside a network of 1-D channels. The cooling circuit consists of the beam dump (inner cone and shroud made of EDP Cu (electrodeposited copper) and the cylinder made of SS304L), the piping from the cooling skid to the beam dump cell and the cooling skid itself composed of the heat exchanger, the purifying loop and the pump. Corrosion is an issue that deserves attention because of radioprotection reasons and because it could affect the cartridge thermomechanical performance. A simulation with TRACT for a water pH of 7 at the beam dump entrance has been performed, showing corrosion rates (< 1 g/(m2 year)) which do not compromise the beam dump performance.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fusion Engineering and Design - Volume 88, Issues 6–8, October 2013, Pages 827–830
نویسندگان
, , , , , ,