کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2761480 1150195 2007 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of Dexamethasone on Atrial Fibrillation After Cardiac Surgery: Prospective, Randomized, Double-Blind, Placebo-Controlled Trial
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی بیهوشی و پزشکی درد
پیش نمایش صفحه اول مقاله
Effect of Dexamethasone on Atrial Fibrillation After Cardiac Surgery: Prospective, Randomized, Double-Blind, Placebo-Controlled Trial
چکیده انگلیسی

Objective: The purpose of this study was to assess the effect of preoperative dexamethasone (DEX) on the occurrence of postoperative atrial fibrillation (AF).Design: Prospective, randomized, double-blind, placebo-controlled clinical trial.Setting: Tertiary referral center.Participants: Seventy-eight adult patients undergoing combined valve and coronary artery bypass graft (CABG) surgery were randomized to receive either DEX or placebo.Interventions: The DEX group received dexamethasone, 0.6 mg/kg, after induction of anesthesia, and the placebo group received an equal volume of normal saline. Interleukin (IL)-6, -8, and -10; tumor necrosis factor α; and endothelin (ET)-1 were measured preoperatively and on postoperative days (POD) 1, 2, and 3. Complement (C-4) and C-reactive protein (CRP) were measured preoperatively and on POD 2. Exhaled nitric oxide (NO) was measured preoperatively, 15 minutes after aortic unclamping, and 1 hour after intensive care unit admission.Measurements and Main Results: No significant difference in the incidence of AF was found between the placebo (41%) and DEX groups (30%) (95% confidence interval [−11%, 34%); p = 0.31). DEX significantly reduced at least 1 postoperative level of IL-6, IL-8, IL-10, CRP, and exhaled NO. DEX did not affect ET-1 or C-4 levels. IL-10 on POD 3 was positively correlated with postoperative hospital length of stay (r = 0.30, p = 0.01). Increased levels of IL-8 and IL-10 on POD 1 were positively correlated with the intubation time (r = 0.31, p = 0.01; r = 0.30, p = 0.01, respectively). Conversely, C-4 on POD 2 was negatively correlated with the intubation time and intensive care unit length of stay (r = −0.32, p = 0.006; r = −0.30, p = 0.01, respectively).Conclusions: DEX did not affect the incidence of AF in patients undergoing combined CABG and valve surgery. However, it did modulate the release of several inflammatory and acute-phase response mediators that are associated with adverse outcomes.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cardiothoracic and Vascular Anesthesia - Volume 21, Issue 1, February 2007, Pages 68–75
نویسندگان
, , , , , , , ,