کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
276266 1429550 2012 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Effect of the column height on the performance of liquid–solid fluidized bed for the separation of coarse slime
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات زمین شناسی اقتصادی
پیش نمایش صفحه اول مقاله
Effect of the column height on the performance of liquid–solid fluidized bed for the separation of coarse slime
چکیده انگلیسی

A liquid–solid fluidized bed separator, used for the separation of coarse slime, was developed. Test particles sized in the range from 0.25 to 0.5, 0.5 to 1.0, and 0.25 to 1.0 mm were separated in the liquid–solid fluidized bed. Beds with column heights of 1200, 1500, and 1800 mm were tried. The clean coal and the tailings were subsequently analyzed by float–sink testing. The results showed that the ash and yield of clean coal both decreased with increasing column height, for all three size fractions, and that the ash of the clean coal obtained from tests on the broader size fraction was less than that from the narrower sized fractions. The separation density decreased with increasing column height. The lowest E value was seen for a column height of 1500 mm, for which conditions the separation density was 1.45 g/cm3. The E value was 0.084 for the 0.25–0.5 mm fraction but the corresponding separation density was 1.48 g/cm3, and the E value 0.089, for the broader 0.25–1.0 mm fraction.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Mining Science and Technology - Volume 22, Issue 4, July 2012, Pages 585–588
نویسندگان
, , , , ,