کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2940562 1177037 2013 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Automated 3-Dimensional Aortic Annular Assessment by Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Automated 3-Dimensional Aortic Annular Assessment by Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
چکیده انگلیسی

ObjectivesThis study sought to evaluate the accuracy, reproducibility, and predictive value for post-procedural aortic regurgitation (AR) of an automated multidetector computed tomography (MDCT) post-processing imaging software, 3mensio Valves (version 5.1.sp1, 3mensio Medical Imaging BV, the Netherlands), in the assessment of patients undergoing transcatheter aortic valve implantation (TAVI).BackgroundAccurate pre-operative aortic annulus measurements are crucial for patients undergoing TAVI.MethodsOne hundred five patients undergoing MDCT screening before TAVI were evaluated. Aortic annular measurement was compared between automated 3mensio Valves software and manual data post-processing software on a dedicated workstation; we analyzed the discrimination value of annulus measurement for post-procedural AR in 44 recipients of a self-expanding valve.ResultsThe automated 3mensio Valves software showed good concordance with manual MDCT measurements as demonstrated by Bland-Altman analysis. The automated software provided equally good reproducibility as manual measurement, especially for measurement of aortic annulus area (intraobserver intraclass correlation coefficients 0.98 vs. 0.97, interobserver 0.98 vs. 0.95). In 44 patients after implantation of a self-expanding valve, the valve diameter/CT-measured geometric mean annulus diameter ratio by automated 3mensio Valves software showed moderate and better discrimination ability in predicting post-procedural AR compared with manual measurement (p = 0.12, area under the curve 0.77, 95% confidence interval: 0.63 to 0.91, area under the curve 0.68, 95% confidence interval: 0.50 to 0.86, respectively).ConclusionsThe automated 3mensio Valves software demonstrated reliable, reproducible aortic annulus measurement and better predictive value for post-procedural AR, suggesting important clinical implications for pre-operative assessment of patients undergoing TAVI.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 6, Issue 9, September 2013, Pages 955–964
نویسندگان
, , , , , , , , , , , , ,