کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2942026 1177097 2009 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Impact of Post-Intervention Minimal Stent Area on 9-Month Follow-Up Patency of Paclitaxel-Eluting Stents : An Integrated Intravascular Ultrasound Analysis From the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Impact of Post-Intervention Minimal Stent Area on 9-Month Follow-Up Patency of Paclitaxel-Eluting Stents : An Integrated Intravascular Ultrasound Analysis From the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials
چکیده انگلیسی

ObjectivesWe investigated the predictive value of the intravascular ultrasound (IVUS) measured post-intervention minimum stent area (MSA) on 9-month follow-up paclitaxel-eluting stent (PES) patency compared with bare-metal stents (BMS).BackgroundStent underexpansion is a strong predictor for restenosis after sirolimus-eluting stent implantation, but the implication of underexpansion in PES is still unknown.MethodsFrom the combined TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent trials, 1,580 patients (PES 1,098, BMS 482) in IVUS substudies were analyzed. The MSA that best predicted angiographic in-stent restenosis (ISR) (% diameter stenosis ≥50%) was determined.ResultsThe post-intervention IVUS MSA was similar in PES and BMS (6.6 ± 2.5 mm2 vs. 6.7 ± 2.3 mm2, p = 0.92). At 9-month follow-up, ISR was lower in the PES group versus the BMS group (10% vs. 31%, p < 0.0001). Using multivariable logistic regression analysis, post-intervention IVUS MSA was the independent predictor of subsequent ISR in both the PES and BMS groups (p = 0.0002 for PES and p = 0.0002 for BMS). The ability of the post-intervention IVUS MSA to predict ISR was further assessed using receiver operating characteristic analysis. The post-intervention IVUS MSA was found to be a faithful discriminator between patients with and without ISR in both PES (c = 0.6382) and BMS (c = 0.6373). Finally, the optimal thresholds of post-intervention IVUS MSA that best predicted stent patency at 9 months were 5.7 mm2 for PES and 6.4 mm2 for BMS.ConclusionsPost-intervention MSA measured by IVUS can predict 9-month follow-up stent patency after both PES and BMS implantation. (Randomized Trial Evaluating Slow-Release Formulation TAXUS Paclitaxel-Eluting Coronary Stents to Treat De Novo Coronary Lesions; NCT00301522) (Direct Stenting of TAXUS Liberté-SR Stent for the Treatment of Patients With de Novo Coronary Artery Lesions; NCT00371423) (A Study of the TAXUS Liberté Stent for the Treatment of Long De Novo Coronary Artery Lesions; NCT00371475) (A Study of the TAXUS Liberté Stent for the Treatment of de Novo Coronary Artery Lesions in Small Vessels; NCT00371748)

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 2, Issue 12, December 2009, Pages 1269–1275
نویسندگان
, , , , , , , , , , , , , ,