کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2942131 1177102 2008 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Head-to-Head Comparison of Coronary Plaque Evaluation Between Multislice Computed Tomography and Intravascular Ultrasound Radiofrequency Data Analysis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Head-to-Head Comparison of Coronary Plaque Evaluation Between Multislice Computed Tomography and Intravascular Ultrasound Radiofrequency Data Analysis
چکیده انگلیسی

ObjectivesThe purpose of this study was to perform a head-to-head comparison of plaque observations with multislice computed tomography (MSCT) to virtual histology intravascular ultrasound (VH IVUS).BackgroundThe VH IVUS allows in vivo coronary plaque characterization with high spatial resolution. Noninvasively, plaques may be evaluated with MSCT, but limited data are available.MethodsA total of 50 patients underwent 64-slice MSCT followed by VH IVUS. The Agatston score was evaluated on MSCT in coronary segments where IVUS was performed. Plaques were classified on MSCT as noncalcified, mixed, and calcified. Four plaque components (fibrotic, fibro-fatty, and necrotic core tissues and dense calcium) were identified on VH IVUS, and the presence of thin-cap fibroatheroma was evaluated.ResultsA moderate correlation was observed between the Agatston score and calcium volume on VH IVUS (r = 0.69, p < 0.0001). In total, 168 coronary plaques were evaluated (48 [29%] noncalcified, 71 [42%] mixed, 49 [29%] calcified). As compared with calcified plaques, noncalcified plaques contained more fibrotic (60.90 ± 9.21% vs. 54.60 ± 8.33%, p = 0.001) and fibro-fatty tissues (28.11 ± 13.03% vs. 21.37 ± 9.75%, p = 0.006) on VH IVUS. Mixed and calcified plaques contained more dense calcium (7.61 ± 8.94% vs. 2.68 ± 3.01%, p = 0.001; 10.18 ± 6.71% vs. 2.68 ± 3.01%, p < 0.0001, respectively). Thin-cap fibroatheromas were most frequently observed in mixed plaques as compared with noncalcified and calcified plaques (32%, 13%, 8%, p = 0.002, respectively).ConclusionsA good correlation was observed between calcium quantification on MSCT and VH IVUS. In addition, plaque classification on MSCT paralleled relative plaque composition on VH IVUS, although VH IVUS provided more precise plaque characterization. Mixed plaques on MSCT were associated with high-risk features on VH IVUS.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: JACC: Cardiovascular Interventions - Volume 1, Issue 2, April 2008, Pages 176–182
نویسندگان
, , , , , , , , , ,