کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2951569 1577332 2010 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Optimizing Hemodynamics in Heart Failure Patients by Systematic Screening of Left Ventricular Pacing Sites : The Lateral Left Ventricular Wall and the Coronary Sinus Are Rarely the Best Sites
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Optimizing Hemodynamics in Heart Failure Patients by Systematic Screening of Left Ventricular Pacing Sites : The Lateral Left Ventricular Wall and the Coronary Sinus Are Rarely the Best Sites
چکیده انگلیسی

ObjectivesWe sought to evaluate the impact of the left ventricular (LV) pacing site on hemodynamic response to cardiac resynchronization therapy (CRT).BackgroundCRT reduces morbidity and mortality in heart failure patients. However, 20% to 40% of eligible patients may not fully benefit from CRT device implantation. We hypothesized that selecting the optimal LV pacing site could be critical in this issue.MethodsThirty-five patients with nonischemic dilated cardiomyopathy referred for CRT device implantation were studied. Intraventricular dyssynchrony and latest activated LV wall were defined by tissue Doppler imaging analysis before the study. Eleven predetermined LV pacing sites were systematically assessed in random order: basal and mid-cavity (septal, anterior, lateral, inferior), apex, coronary sinus (CS), and the endocardial site facing the CS pacing site. For each patient, +dP/dTmax, −dP/dTmin, pulse pressure, and end-systolic pressure during baseline (AAI) and DDD LV pacing were compared. Two atrioventricular delays were tested.ResultsMajor interindividual and intraindividual variations of hemodynamic response depending on the LV pacing site were observed. Compared with baseline, LV DDD pacing at the best LV position significantly improved +dP/dTmax(+31 ± 26%, p < 0.001) and was superior to pacing the CS (+15 ± 23%, p < 0.001), the lateral LV wall (+18 ± 22%, p < 0.001), or the latest activated LV wall (+11 ± 17%, p < 0.001).ConclusionsThe pacing site is a primary determinant of the hemodynamic response to LV pacing in patients with nonischemic dilated cardiomyopathy. Pacing at the best LV site is associated acutely with fewer nonresponders and twice the improvement in +dP/dTmaxobserved with CS pacing.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 55, Issue 6, 9 February 2010, Pages 566–575
نویسندگان
, , , , , , , , , , , , , , ,