کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2953811 1577419 2008 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The Right Ventricular Failure Risk Score: A Pre-Operative Tool for Assessing the Risk of Right Ventricular Failure in Left Ventricular Assist Device Candidates
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
The Right Ventricular Failure Risk Score: A Pre-Operative Tool for Assessing the Risk of Right Ventricular Failure in Left Ventricular Assist Device Candidates
چکیده انگلیسی

ObjectivesThis study sought to develop a model that estimates the post-operative risk of right ventricular (RV) failure in left ventricular assist device (LVAD) candidates.BackgroundRight ventricular failure after LVAD surgery is associated with increased morbidity and mortality, but identifying LVAD candidates at risk for RV failure remains difficult.MethodsA prospectively collected LVAD database was evaluated for pre-operative clinical, laboratory, echocardiographic, and hemodynamic predictors of RV failure. Right ventricular failure was defined as the need for post-operative intravenous inotrope support for >14 days, inhaled nitric oxide for ≥48 h, right-sided circulatory support, or hospital discharge on an inotrope. An RV failure risk score (RVFRS) was created from multivariable logistic regression model coefficients, and a receiver-operating characteristic curve of the score was generated.ResultsOf 197 LVADs implanted, 68 (35%) were complicated by post-operative RV failure. A vasopressor requirement (4 points), aspartate aminotransferase ≥80 IU/l (2 points), bilirubin ≥2.0 mg/dl (2.5 points), and creatinine ≥2.3 mg/dl (3 points) were independent predictors of RV failure. The odds ratio for RV failure for patients with an RVFRS ≤3.0, 4.0 to 5.0, and ≥5.5 were 0.49 (95% confidence interval [CI] 0.37 to 0.64), 2.8 (95% CI 1.4 to 5.9), and 7.6 (95% CI 3.4 to 17.1), respectively, and 180-day survivals were 90 ± 3%, 80 ± 8%, and 66 ± 9%, respectively (log rank for linear trend p = 0.0045). The area under the receiver-operating characteristic curve for the RVFRS (0.73 ± 0.04) was superior to that of other commonly used predictors of RV failure (all p < 0.05).ConclusionsThe RVFRS, composed of routinely collected, noninvasive pre-operative clinical data, effectively stratifies the risk of RV failure and death after LVAD implantation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 51, Issue 22, 3 June 2008, Pages 2163–2172
نویسندگان
, , , ,