کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
2954247 1577524 2006 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Characterization of Radiofrequency Ablation Lesions With Gadolinium-Enhanced Cardiovascular Magnetic Resonance Imaging
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Characterization of Radiofrequency Ablation Lesions With Gadolinium-Enhanced Cardiovascular Magnetic Resonance Imaging
چکیده انگلیسی

ObjectivesThis study was designed to evaluate the characteristics of gadolinium-enhanced imaging of radiofrequency ablations.BackgroundGadolinium-enhanced magnetic resonance imaging (MRI) has been used successfully to evaluate tissue necrosis after myocardial infarction. In electrophysiology, radiofrequency energy is used to create a targeted myocardial necrosis for the treatment of various arrhythmias.MethodsUsing a power-controlled, cooled-tip 7-F catheter system, radiofrequency lesions (10 to 40 W for 30 s) were created on the epicardium of the right ventricle in eight mongrel dogs. After injection of 0.225 mmol/kg gadolinium, T1-weighted fast gradient echo images were obtained during a follow-up of 10 h using an intrathoracic high-resolution coil. Radiofrequency ablations were analyzed on the MR images and compared with gross anatomy and histopathology.ResultsFour distinct phases of signal enhancement were observed. After gadolinium injection, radiofrequency lesions were delineated clearly as contrast-free areas of low signal intensity (contrast-to-noise ratio [CNR] = −21.1 ± 19.8). Signal enhancement in the lesion periphery started 4.0 ± 1.8 min after injection and progressively extended toward the lesion center at a rate of 0.02 mm/min. Full delayed enhancement was observed after 98 ± 21 min (CNR = +17.8 ± 9.0). During the follow-up period, CNR started to decrease, but the lesions were detectable for as long as 10 h of follow-up. During the first three phases of enhancement, MRI correlated well with the pathological findings (r = 0.88, r = 0.88, and r = 0.86 [p < 0.001], respectively).ConclusionsRadiofrequency ablation can be evaluated accurately by using gadolinium-enhanced MRI, which may allow the noninvasive assessment of procedural success. The dissimilar wash-in and wash-out kinetics compared with myocardial infarction suggest a different pathophysiological process with complete loss of microvasculature.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the American College of Cardiology - Volume 47, Issue 2, 17 January 2006, Pages 370–378
نویسندگان
, , , , , , , , , , ,