کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
2968505 | 1178877 | 2010 | 5 صفحه PDF | دانلود رایگان |

IntroductionThe purpose of our study was to prove the existence of the U wave using magnetocardiograms (MCGs).MethodsThe 31-channel MCGs of 25 healthy volunteers were recorded. The onset of the U wave was defined by newly developed spatial correlation analysis; and the end, by different approaches.ResultsA U wave could be proved in all volunteers. In 10 volunteers (heart rate, 57 ± 19 beats/min) in whom the U wave was found to be separated from the following P wave, the U wave's end could be determined as a threshold value (U wave duration, 310 ± 24 milliseconds). In 15 volunteers (heart rate, 70 ± 38 beats/min), the end of the U waves was concealed by a continuous transition of the U waves into the following P waves.ConclusionsThe U wave seems to be a regular phenomenon and has a distinct spatiotemporal assembly.
Journal: Journal of Electrocardiology - Volume 43, Issue 1, January–February 2010, Pages 43–47