کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3008983 1181473 2012 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Quantitative waveform measures of the electrocardiogram as continuous physiologic feedback during resuscitation with cardiopulmonary bypass
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
پیش نمایش صفحه اول مقاله
Quantitative waveform measures of the electrocardiogram as continuous physiologic feedback during resuscitation with cardiopulmonary bypass
چکیده انگلیسی

BackgroundThere are few if any real-time physiologic measures that currently provide feedback during resuscitation from cardiac arrest. Such measures could be used to guide therapy not simply based on process guidelines but on the physiologic response of the patient from moment to moment. To this end, we applied an existing technology – quantitative waveform measures (QWMs) of the ventricular fibrillation (VF) electrocardiogram (ECG) – as a continuous measure of myocardial response to reperfusion with cardiopulmonary bypass (CPB) after prolonged cardiac arrest.MethodsSixteen domestic, mixed-breed swine were sedated, anesthetized and paralyzed. Mechanical ventilation with room air was provided. Large diameter bypass catheters were placed in the right external jugular vein and right femoral artery for cardiopulmonary bypass (CPB). VF was induced with a 3-s 100 mA transthoracic shock and left untreated for 15, 20, 25, or 30 min, followed by 10 min of centrifugal pump CPB (Bard CPS). Continuous Lead II ECG was recorded with an electronic data acquisition system (Power Lab, ADInstruments). Four QWMs representing 4 signal characteristics of the VF ECG were calculated in 5-s windows throughout the course of untreated VF and resuscitation with CPB.ResultsFour animals were assigned to each VF duration group. QWM recovery was inversely correlated with untreated VF duration, and was drastically reduced above 20 min of untreated VF. Return of spontaneous circulation (ROSC) was highly unlikely after 20 min of untreated VF.ConclusionQWMs of the VF ECG provided a real-time metric of myocardial electrophysiologic response to reperfusion with CPB. Resuscitation from greater than 20 min of untreated cardiac arrest was unlikely. QWMs may be useful for titrating CPB duration before defibrillation and assessing CPR quality independently of process guidelines.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Resuscitation - Volume 83, Issue 4, April 2012, Pages 505–510
نویسندگان
, , , , , , ,