کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
306890 513121 2006 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Development of on-line measurement system of bulk density based on on-line measured draught, depth and soil moisture content
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
پیش نمایش صفحه اول مقاله
Development of on-line measurement system of bulk density based on on-line measured draught, depth and soil moisture content
چکیده انگلیسی

On-line measurement of soil compaction is needed for site specific tillage management. The soil bulk density (ρ) indicating soil compaction was measured on-line by means of a developed compaction sensor system that comprised several sensors for on-line measurement of the draught (D) of a soil cutting tool (subsoiler), the soil cutting depth (d  ) and the soil moisture content (ww). The subsoiler D was measured with a single shear beam load cell, whereas d   was measured with a wheel gauge that consisted of a swinging arm metal wheel and a linear variable differential transducer (LVDT). The soil ww was measured with a near infrared fibre-type spectrophotometer sensor. These on-line three measured parameters were used to calculate ρ, by utilising a hybrid numerical–statistical mathematical model developed in a previous study. Punctual kriging was performed using the variogram estimation and spatial prediction with error (VESPER) 1.6 software to develop the field maps of ρ  , soil ww, subsoiler d and D, based on 10 m × 10 m grid. To verify the on-line measured ρ map, this map was compared with the map measured by the conventional core sampling method.The spherical semivariogram models, providing the best fit for all properties was used for kriging of different maps. Maps developed showed that no clear correlation could be detected between different parameters measured and subsoiler D. However, the D value was smaller at shallow penetration d, whereas large D coincided with large ρ values at few positions in the field. Maps of ρ measured with the core sampling and on-line methods were similar, with correlation coefficient (r) and the standard error values of 0.75 and 0.054 Mg m−3, respectively. On-line measured ρ exhibited larger errors at very dry zones. The normal distribution of the ρ error between the two different measurement methods showed that about 72% of the errors were less than 0.05 Mg m−3 in absolute values. However, the overall mean error of on-line measured ρ was of a small value of 2.3%, which ensures the method accuracy for on-line measurement of ρ. Measurement under very dry conditions should be minimised, because it can lead to a relatively large error, and hence, compacted zones at dry zones cannot be detected correctly.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Soil and Tillage Research - Volume 86, Issue 2, April 2006, Pages 218–229
نویسندگان
, ,