کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3167678 1199376 2010 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A biomechanical analysis of titanium miniplates used for treatment of mandibular symphyseal fractures with the finite element method
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی دندانپزشکی، جراحی دهان و پزشکی
پیش نمایش صفحه اول مقاله
A biomechanical analysis of titanium miniplates used for treatment of mandibular symphyseal fractures with the finite element method
چکیده انگلیسی

ObjectiveThis study aimed to evaluate the stress distribution and stress shielding effect of titanium miniplates used for the treatment of symphyseal fractures using finite element (FE) analysis.Study designTwo 3-D FE models of symphyseal fractured mandibles reduced by technique 1, reduction with a single miniplate, and technique 2, reduction with 2 miniplates, respectively, were developed. Three basic loading conditions were simulated.ResultsThe ratios of stress shielding of miniplates were different. Ratios of the lower miniplates in technique 2 were much higher than the upper miniplates and the miniplates in technique 1 during all conditions, and that value of the lower miniplate gained a maximum value of 83.34% during left unilateral molar clenching. The stress areas were concentrated on the central section of the miniplates. However, the stress distribution varied with masticatory conditions.ConclusionThe study demonstrated that miniplate stress distribution and stress shielding effect ratio were affected not only by the way in which the mandible was loaded but also by the number of the miniplates fixing the fracture.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology - Volume 109, Issue 3, March 2010, Pages e21–e27
نویسندگان
, , , , , ,