کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
3240241 1206037 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Reduction and fixation capabilities of different plate designs for pubic symphysis disruption: A biomechanical comparison
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
پیش نمایش صفحه اول مقاله
Reduction and fixation capabilities of different plate designs for pubic symphysis disruption: A biomechanical comparison
چکیده انگلیسی

BackgroundTypical stabilisation of pelvic open book injuries consists in plate fixation of the symphysis, leading to many different plate designs and procedures that have evolved. However, implant loosening and development of chronic instability are still evident and represent major complications after plate fixation of the symphysis. The aim of this study was to analyse reduction and fixation capabilities of different classical plate techniques with dynamic compression (DC), prebending or modern interlocking screws.MethodsCompression injuries (OTA B1.1) were simulated on synthetic composite pelvises. Sensor films placed in the disrupted symphysis allowed assessment of reduction and compression forces, as well as contact characteristics by implants at defined time points under static non loaded conditions. The commercially available steel plates used in our study differed in curved design, prebending and DC- or locking screw capabilities, as narrow large fragment (4.5) or small fragment plates (3.5).ResultsDC procedure clearly increased the compressive force in the symphysis and improved the reduction by enhanced contact areas. These effects were preserved to the end of the experiments only when the plates were prebended (10°). Anatomically contoured and prebended 3.5 plates had a similar effect, but the contact area was even more pronounced. Best results were observed using the “3.5 symphyseal plate” with DC-effect medially and locking screws laterally. Purely interlocking screw plates by themselves allowed an optimal contact area, yet failed to preserve the initial compressive reduction force.ConclusionsThe experimental results suggest a biomechanical advantage in using prebended plates for symphysis fixation compared to non-bended plates. Best results with regard to compression and increased contact area can be achieved by anatomically contoured plates with combined DC and locking screw capabilities. These findings are of special interest in pelvic surgery for choosing the right implant in severe displacements, obese patients and symphysiodesis techniques.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Injury - Volume 44, Issue 2, February 2013, Pages 183–188
نویسندگان
, , , , ,