کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
3240351 | 1206040 | 2013 | 6 صفحه PDF | دانلود رایگان |
IntroductionThe biomechanical properties of extra-articular fractures of the distal humerus have not been researched sufficiently. The aim of the study was to examine three different models of osteosynthesis for extra-articular distal humerus fractures. Osteosynthesis with two parallel or perpendicular plates is a common method of osteosynthesis for those fractures. We wanted to examine the biomechanical performance of a newly designed Y plate, and compare it to the previously used osteosynthesis methods.Materials and methodsOn an osteoporotic computational model of the distal humerus, a 10 mm gap was made, 25 mm above the olecranon fossa, and osteosynthesis was performed with the newly designed Y-shaped plate and with 3.5 reconstruction plates in parallel and perpendicular configuration. The numerical simulations in axial compression, bending and varus loading were conducted using the finite element method.ResultsOn all models the largest displacements in the area of the fracture gap appear around the lower anterior edge. The parallel plate construct had the highest stiffness among the three plating techniques in axial compression. In bending and varus loading the construct with the newly designed plate had the highest stiffness, but in axial compression demonstrated the lowest. The parallel plate configurations had higher stiffness than the perpendicular ones in all three loading directions and the difference is most pronounced in axial compression.ConclusionThe displacements that appeared in all three plating systems are minimal and within the limits that meet the requirements of sufficient biomechanical stability in the usual time for the healing of fractures in that region. The newly designed Y-shaped plate for extra-articular fractures of the distal humerus is a possible alternative to the usual method of osteosynthesis with two plates in the case of an extra-articular fracture of the distal humerus. Further biomechanical studies are needed for a decisive conclusion.
Journal: Injury - Volume 44, Supplement 3, September 2013, Pages S56–S61