کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4046358 | 1603567 | 2009 | 10 صفحه PDF | دانلود رایگان |

PurposeA sheep study was conducted to test a press-fit technique using microporous pure β–tricalcium phosphate (β-TCP) dowels for fixation of the anterior cruciate ligament (ACL) graft.MethodsMicroporous (5 μm) cylindrical plugs of β-TCP (diameter, 7 mm; length, 25 mm) with interconnecting pores were used. The material featured a novel configuration of structure and surface geometry. Implants were tested by use of press-fit fixation of ACL grafts with and without bone blocks in 42 sheep over a period of 24 weeks. Biomechanical, radiologic, histologic, and immunohistochemical evaluations were performed.ResultsIn load-to-failure tests at 6, 12, and 24 weeks after surgery, the intra-articular graft always failed, not the fixation. Grafts showed bony fixation in the tunnel at 6 weeks and primary healing at the junction of the tunnel and joint after 24 weeks. Tricalcium phosphate was resorbed and simultaneously replaced by bone. Remodeling was still incomplete at 24 weeks.ConclusionsIn the sheep model microporous β-TCP implants used with press-fit fixation of ACL grafts permit early functional rehabilitation. After 6 weeks, the graft is fixed by woven bone or bony integration. Implanted microporous tricalcium phosphate is resorbed and replaced by bone.Clinical RelevanceIn a sheep model we showed that primary healing of ACL grafts with resorption and bony replacement of the fixating implant can be achieved by means of press-fit fixation with pure β-TCP.
Journal: Arthroscopy: The Journal of Arthroscopic & Related Surgery - Volume 25, Issue 9, September 2009, Pages 996–1005